Consort
Consort develops a wide range of high technology products from simple and robust field-meters up to sophisticated precision laboratory equipment. There are our well-known meters and controllers for pH, mV, ion analysis, rH2, temperature, conductivity, resistivity, salinity, TDS and dissolved oxygen. For the molecular biology field, we offer a wide range of electrophoresis equipment such as high voltage power supplies, horizontal and vertical apparatus, DNA sequencers, blotting units, UV-tables and photo-documentation system.
Gel Systems
Electrophoresis, also called cataphoresis, is the motion of dispersed particles relative to a fluid under the influence of a spatially uniform electric field. This electrokinetic phenomenon was observed for the first time in 1807 by Reuss (Moscow State University), who noticed that the application of a constant electric field caused particles dispersed in water to migrate. It is ultimately caused by the presence of a charged interface between the particle surface and the surrounding fluid.
E3xxx
horizontal units
Rapid (horizontal) systems
E3100 Mini rapid system
For routine, rapid checking of samples
- Gel dimensions (WxL): 10×8 cm
- Buffer volume: 50 ml
- Maximum sample capacity: 40
- Unit dimensions (WxDxH): 15x15x4 cm
- Recommended power supplies: EV222, EV243
E3200 Complete mini horizontal system
Designed for quick checks of low to medium numbers of samples
- Gel Dimensions (WxL): 7×7 or 7×10 cm
- Buffer volume: 225 ml
- Maximum sample capacity: 64
- Unit dimensions (WxDxH): 21x9x9 cm
- Recommended power supplies: EV222, EV243, EV231
E3300 Complete midi horizontal system
Ideal for quick checks of samples from PCR and cloning
- Gel dimensions (WxL): 10×7 or 10×10 cm
- Buffervolume: 300 ml
- Maximum sample capacity: 100
- Unit dimensions (WxDxH): 22×12.5×9 cm
- Recommanded power supplies: EV222, EV243, EV231
E3400 Complete midi-plus horizontal system
Ideal for restriction fragment analysis, sample prep or checking of high numbers of samples
- Gel dimensions (WxL): 15×7, 15×10 or 15×15 cm
- Buffervolume: 500 ml
- Maximum sample capacity: 210
- Unit dimensions (WxDxH): 26.5×17.5×9 cm
- Recommanded power supplies: EV243, EV231
E3500 Complete maxi horizontal system
Primarly designed for separating high numbers of samples PCR or cloning
- Gel dimensions (WxL): 20×10, 20×20 or 20×25 cm
- Buffervolume: 1200 ml
- Maximum sample capacity: 550
- Unit dimensions (WxDxH): 39.5x23x9 cm
- Recommanded power supplies: EV231, EV265
E3600 Complete maxi-plus horizontal system
Ideal for checking very large numbers of samples or extended high resolution separations
- Gel dimensions (WxL): 26×16, 26×24 or 26×32 cm
- Buffervolume: 1400 ml
- Maximum sample capacity: 672
- Unit dimensions (WxDxH): 50x28x9 cm
- Recommanded power supplies: EV265, EV215
E4xxx
vertical units
Vertical systems
E4100 Mini vertical system (also available as Modular system)
Mini SDS PAGE, Native Page, Grandient, Second dimension and Nucleic acid separations
- Plate dimensions (WxL): 10×10 cm
- Gel dimensions (WxL): 7.5×8 cm
- Buffervolume: 250…1200 ml
- Maximum sample capacity: 80 (20 per gel)
- Recommanded power supplies: EV243, EV231
- E4200 Mini-wide vertical system
Mini SDS PAGE, Native Page, Grandient, Second dimension and Nucleic acid separations
- Plate dimensions (WxL): 20×10 cm
- Gel dimensions (WxL): 18×8 cm
- Buffervolume: 600…2800 ml
- Maximum sample capacity: 192 (48 per gel)
- Unit dimensions (WxDxH): 26x16x16 cm
- Recommanded power supplies: EV231, EV265
E4300 Maxi vertical system
Mini SDS PAGE, Native Page, Grandient, Second dimension and Nucleic acid separations
- Plate dimensions (WxL): 20×20 cm
- Gel dimensions (WxL): 16×17.5 cm
- Buffervolume: 1200…5600 ml
- Maximum sample capacity: 192 (48 per gel)
- Unit dimensions (WxDxH): 26x16x28 cm
- Recommanded power supplies: EV265, EV215
E4400 Denaturing gradient unit
Detection of single base changes and polymorhisms in genomic cloned and amplified DNA fragments
- Plate dimensions (WxL): 20×20 cm
- Gel dimensions (WxL): 16×17.5 cm
- Buffervolume: 1200…5600 ml
- Maximum sample capacity: 192 (48 per gel)
- Unit dimensions (WxDxH): 26x16x28 cm
- Recommanded power supplies: EV265, EV215
E4500 Sequencing unit
- Plate dimensions (WxL): 33×45 cm
- Buffervolume: 800…2000 ml
- Maximum sample capacity: 96
- Recommanded power supplies: EV232, EV233
E5xxx
blotting units
Blotting units, these stand alone, complete units for electroblotting, mini, mini-wide and maxi formats, include vertical tank and lid, electroblotting insert, cassettes and fibre pads.
- E5100 Blotting unit
- Mini blotter: tank & lid + 4 cassettes 10×10 cm + 8 fibre pads + cooling pack
- E5100 Blotting unit
- Mini-wide blotter: tank & lid + 3 cassettes 20×10 cm + 6 fibre pads + cooling pack
- E5300 Blotting unit
- Maxi blotter: tank & lid + 3 cassettes 20×20 cm + 6 fibre pads + cooling pack
Semi dry blotters
The semi-dry blotters offer rapid transfer times for DNA, RNA and protein blotting (typically 15 to 30 minutes).
- E5400 Semi-dry blotter
- Semi-dry blotter, mini, 10×10 cm
- E5500 Semi-dry blotter
- Semi-dry blotter, midi, 20×20 cm
- E5600 Semi-dry blotter
- Semi-dry blotter, maxi, 33×45 cm
- E5700 Semi-dry blotter
- Semi-dry blotter, long, 20×50 cm
E3700
cellulose acetate systems
E3700 Horizontal unit
Clinical electrophoresis tests: Haemoglobin, Serum Proteins for Monoclonal Gammapathies, Urine proteins, Isoenzymes, Lipo and Glycoproteins and for Immunofixation
Clinical Electrophoresis tests:
- haemoglobin
- serum proteins for monoclonal gammapathies
- urine proteins
- isoenzymes
- lipo and glycoproteins
- immunofixation
E3700 horizontal system, 24×20 cm
E3800
flatbed isoelectric focusing system
E3800 isolectric system
- For IEF strip and gel applications
- Large cooling platform area
- Pick and place easy to postion electrodes
- Grid for accurate electrode alignment
E3800 isoelectric focusing system, 26×26 cm