Consort
Consort develops a wide range of high technology products from simple and robust field-meters up to sophisticated precision laboratory equipment. There are our well-known meters, electrodes and controllers for pH, mV, ion analysis, rH2, temperature, conductivity, resistivity, salinity, TDS and dissolved oxygen. For the molecular biology field, we offer a wide range of electrophoresis equipment such as high voltage power supplies, horizontal and vertical apparatus, DNA sequencers, blotting units, UV-tables and photo-documentation system.
Electrodes
An electrode is an electrical conductor used to make contact with a nonmetallic part of a circuit semiconductor, anelectrolyte or a vacuum). The word was coined by the scientist Michael Faraday from the Greek words elektron (meaning , from which the word electricity is derived) and hodos, a way.
GOOD MEASUREMENT PRACTICES
– While calibrating or measuring all solutions should be stirred gently (e.g. with a magnetic stirrer) to ensure the electrode gives a true representation of the beaker contents.
– Calibration solutions should be chosen which have values near the expected sample value.
– Only fresh calibration solutions should be used! Changing all solutions daily is a good practice.
– All solutions should be maintained at equal temperature.
– Rinse the electrode twice between measurements: first thoroughly in distilled water and then with a small amount of the next sample to be measured.
– Allow the electrodes sufficient time to stabilise while calibrating or measuring. A stability indicator on all of our meters prompts the user when readings should be taken.
Standard Electrodes
for pH, conductivity, dissolved oxygen, temperature (with fixed cable)
Standard electrodes
SP10B pH, epoxy, sealed, 0…14 pH, 0…80°C
SP10T pH + ATC, epoxy, sealed, 0…14 pH, 0…80°C
SP21B pH, glass, sealed, 0…14 pH, 0…100°C
SP21T pH + ATC, glass, sealed, 0…14 pH, 0…100°C
SK10B conductivity, epoxy, 0…80°C, 1 cm-1
SK10T conductivity + ATC, epoxy, 0…80°C, 1 cm-1
SK20B conductivity, glass, 0…100°C, 1 cm-1
SK20T conductivity + ATC, glass, 0…100°C, 1 cm-1
SK21T conductivity + ATC, glass, 0…100°C, 0.1 cm-1
SK23T conductivity + ATC, glass, 0…100°C, 10 cm-1
SK24T conductivity + ATC, glass, 0…100°C, 1 cm-1, 6 mm diameter
SZ10T dissolved oxygen + ATC, epoxy, 0…50°C, 3 m cable
ST10N temperature, Pt1000, stainless steel, -30…+130°C
ST20N temperature, Pt1000, glass, -30…+130°C
The standard electrodes will be supplied with 1 m of cable and BNC plug (+2 banana plugs for built-in ATC).
Special Electrodes
for pH, ORP, with S7 plug head (to be used with separate cable)
Special electrodes
SP11X pH, epoxy, sealed, 0…14 pH, 0…100°C
SP21X pH, glass, refillable, 0…14 pH, 0…100°C
SP22X pH, glass, sealed, 0…14 pH, 0…110°C
SP24X pH, spear 25xØ5 mm, sealed, 0…14 pH, 0…80°C
SP26X pH, ground joint, refillable, 0…14 pH, 0…100°C
SP27X pH, flat surface, sealed, 0…14 pH, 0…80°C
SP28X pH, 130xØ4 mm, refillable, 0…14 pH, 0…100°C
SP29X pH, 250xØ12 mm, refillable, 0…14 pH, 0…100°C
SP50X ORP, epoxy, sealed, 0…80°C
SP60X ORP, glass, refillable, 0…100°C
SP65X Ag, glass, refillable, 0…100°C
SP04X double Pt , glass, titration, 0…100°C
SP91X pH, steam sterilisable, 110 mm long, -5…135°C
SP92X pH, steam sterilisable, 120 mm long, -5…135°C
SP93X pH, steam sterilisable, 130 mm long, -5…135°C
SP94X pH, steam sterilisable, 140 mm long, -5…135°C
SP95X pH, steam sterilisable, 210 mm long, -5…135°C
SP96X pH, steam sterilisable, 260 mm long, -5…135°C
SP97X pH, steam sterilisable, 310 mm long, -5…135°C
SP98X pH, steam sterilisable, 360 mm long, -5…135°C
SP99X pH, steam sterilisable, 420 mm long, -5…135°C
The speciality pH electrodes will be supplied with S7 plug head.
Industrial Electrodes
for pH, ORP, conductivity, dissolved oxygen, temperature, with S8 plug head (to be used with separate cable)
Insustrial electrodes
SP11Y pH, epoxy, sealed, 0…14 pH, 0…100°C
SP23Y pH, glass, sealed, 0…14 pH, 0…110°C
SP50Y ORP, epoxy, sealed, 0…80°C
SP61Y ORP, glass, sealed, 0…100°C
SK10Y conductivity, epoxy, 0…80°C, 1 cm-1
SK20Y conductivity, glass, 0…100°C, 1 cm-1
SK22Y conductivity, glass, 0…100°C, 0.1 cm-1
SK23Y conductivity, glass, 0…100°C, 10 cm-1
ST21Y temperature, Pt1000, glass, -30…+130°C
SZ12T dissolved oxygen + Pt1000, epoxy, 0…50°C, 15 m cable
The industrial electrodes will be supplied with S8 plug head.
Combination ion selective Electrodes
with fixed cable and BNC plug
Two versions available: standard (ISE20B…ISE52B) or with replaceable membrane (ISE60B…ISE82B)
Combination electrodes
ISE20B/ISE60B ammonium, combination, 5.10-6…10-0 M, 0…50°C
ISE21B/ISE61B bromide, combination, 5.10-6…10-0 M, 0…50°C
ISE22B/ISE62B cadmium, combination, 10-6…10-1 M, 0…50°C
ISE23B/ISE63B calcium, combination, 5.10-6…10-0 M, 0…50°C
ISE24B/ISE64B chloride, combination, 5.10-5…10-0 M, 0…50°C
ISE25B/ISE65B copper, combination, 10-8…10-1 M, 0…50°C
ISE26B/ISE66B cyanide, combination, 5.10-6…10-2 M, 0…50°C
ISE27B/ISE67B fluoride, combination, 10-6…sat. M, 0…50°C
ISE28B/ISE68B fluorobarate, combination, 7.10-6…10-0 M, 0…50°C
ISE29B/ISE69B iodide, combination, 5.10-8…10-0 M, 0…50°C
ISE30B/ISE70B lead, combination, 10-6…10-1 M, 0…50°C
ISE31B/ISE71B nitrate, combination, 7.10-6…10-0 M, 0…50°C
ISE32B/ISE72B perchlorate, combination, 7.10-6…10-0 M, 0…50°C
ISE33B/ISE73B potassium, combination, 10-6…10-0 M, 0…50°C
ISE34B/ISE74B silver/sulphide, combination, 10-7…10-0 M, 0…50°C
ISE35B sodium, combination, 10-6…sat. M, 0…50°C
ISE36B/ISE76B surfactant, combination, 10-5…5.10-2 M, 0…50°C
ISE37B/ISE77B water hardness, combination, 10-5…10-0 M, 0…50°C
ISE50B/ISE80B ammonia, combination, 5.10-7…10-0 M, 0…50°C
ISE51B/ISE81B carbon dioxides, combination, 10-4…10-2 M, 0…50°C
ISE52B/ISE82B nitrogen oxides, combination, 5.10-6…5.10-3 M, 0…50°C